Tuesday, 26 November 2013

IBM Storwize v7000 - MTU setting

MTU Settings

On the IBM Storwize v7000 I was told the default settings of the MTU was 9000 Jumbo Frames, while dealing with a problem of one of the VMware hosts dropping one of the iSCSI paths, Support suggested I check the MTU setting on the v7000.

After spending a fair bit of time trying to find out how to check the MTU setting and being previously told by IBM you can't change it I found the following.


Command to view settings

lsportip:

Use the lsportip command to list the Internet Small Computer Systems Interface (iSCSI) Internet Protocol (IP) addresses assigned for each port on each node in the clustered system.

Example command: svcinfo lsportip this will display the following.

I used the -delim to seperate it with :

full command:  svcinfo lsportip -delim :

id:node_id:node_name:IP_address:mask:gateway:IP_address_6:prefix_6:gateway_6:MAC:duplex:state:speed:failover:link_state
1:1:node1:::::::e4:1f:13:75:81:xx:Full:unconfigured:1Gb/s:no:active
1:1:node1:::::::e4:1f:13:75:81:xx:Full:unconfigured:1Gb/s:yes:active
2:1:node1:::::::e4:1f:13:75:81:xx:Full:unconfigured:1Gb/s:no:active
2:1:node1:::::::e4:1f:13:75:81:xx:Full:unconfigured:1Gb/s:yes:active
3:1:node1:10.10.11.1:255.255.255.0:10.10.11.254::::00:00:c9:d2:ed:xx:Full:configured:10Gb/s:no:active
3:1:node1:::::::00:00:c9:d2:ed:xx:Full:configured:10Gb/s:yes:active
4:1:node1:10.10.12.1:255.255.255.0:10.10.12.254::::00:00:c9:d2:ed:xx:Full:configured:10Gb/s:no:active
4:1:node1:::::::00:00:c9:d2:ed:xx:Full:configured:10Gb/s:yes:active
1:2:node2:::::::e4:1f:13:75:b0:xx:Full:unconfigured:1Gb/s:no:active
1:2:node2:::::::e4:1f:13:75:b0:xx:Full:unconfigured:1Gb/s:yes:active
2:2:node2:::::::e4:1f:13:75:b0:xx:Full:unconfigured:1Gb/s:no:active
2:2:node2:::::::e4:1f:13:75:b0:xx:Full:unconfigured:1Gb/s:yes:active
3:2:node2:10.10.11.2:255.255.255.0:10.10.11.254::::00:00:c9:d9:4a:xx:Full:configured:10Gb/s:no:active
3:2:node2:::::::00:00:c9:d9:4a:xx:Full:configured:10Gb/s:yes:active
4:2:node2:10..10.12..2:255.255.255.0:10.10.12.254::::00:00:c9:d9:4a:xx:Full:configured:10Gb/s:no:active
4:2:node2:::::::00:00:c9:d9:4a:xx:Full:configured:10Gb/s:yes:active


to see the NIC setting select the appropriate id this can be done by doing the following command:

full command: svcinfo lsportip 1 where 1 is the ethernet port id this will display something similar to the following.

id 1
node_id 2
node_name node2
IP_address
mask
gateway
IP_address_6
prefix_6
gateway_6
MAC e4:1f:13:75:xx:xx
duplex Full
state unconfigured
speed 1Gb/s
failover no
mtu 1500
link_state active


You can see that the MTU is 1500 on the 1Gbs interfaces it is also 1500 on the 10Gbs interfaces 

id 3
node_id 2
node_name node2
IP_address 10.10.11.2
mask 255.255.255.0
gateway 10.10.11.254
IP_address_6
prefix_6
gateway_6
MAC 00:00:c9:d9:xx:xx
duplex Full
state configured
speed 10Gb/s
failover no
mtu 1500
link_state active

To make changes to these setting use svctask cfgportip command.

You can find more details in the IBM v7000 InfoCenter and in the IBM Storwize v7000 Command-Line Interface Users Guide 6.4.1, If you google these you will find them on line.




Friday, 11 October 2013

IBM Storwize v7000 Software v7.2.0

Overview

As of the 8th October 2013 IBM have released details of the new software for the IBM Storwize family, In addition to the software there are new models appearing in the range as well.

The key point for the work I do is that the v7000 now suports IP Replication without employing FCIP (Fibre Channel) IP Routers (FCIP Gateways) such as the IBM SAN06B-R.

IBM are expecting to release this version of software on 29th November 2013.

Functionality

IBM Storwize Family Software V7.2 provides software-defined storage capabilities
across a variety of platforms including SAN Volume Controller, Storwize V7000
(Unified), Flex System V7000, Storwize V5000, and Storwize V3700 and V3500.
These offerings help customers reduce the complexities and cost of managing their
storage through:

• Centralizing management of storage volumes, enabling administrators to manage storage volumes from a single point

• Improving utilization of storage capacity with virtual volumes, enabling businesses to tap into previously unused disk capacity

• Avoiding downtime for backups, maintenance, and upgrades

• Performing data migration without disruption to applications

• Enabling all storage devices to be organized into storage pools from which virtual volumes, whether standard, compressed, or thin-provisioned, are created with the desired characteristics

• Delivering automation of storage management with the Virtual Storage Center, Tivoli® Storage Productivity Center (as applicable by platform), and Tivoli Storage FlashCopy Manager (as applicable by platform)

• Increasing the performance efficiency of storage pools that use SSDs with Easy Tier

• Restoring data access quickly with near and remote copy capabilities across Fibre Channel, Fibre Channel over Ethernet (FCoE), and IP networksIBM Europe, Middle East, and Africa Software Announcement ZP13-0608

More information can be found on the IBM website this is a link to the document.


Friday, 16 August 2013

VMWare and IBM Storwize V7000

I am currently working with IBM Storwize V7000, IBM x3550M4 VMware Hosts, IBM G8124E Blade Network Technology (BNT) Switches, Emulex VFA III 10Gbs Network Cards.

The storage is using 10Gbs ethernet and iSCSI Software initiator, VMware and IBM V7000 don't support the Hardware initiator.

If you would like to see more details of the set up and the hurdles I have come across please go to the following page.

VMware and IBM Storwize V7000

This is a work in progress at the moment and will get updated when I can.